Table of Contents
Fetching ...

Theory of Lineshapes in Optical-Optical Double Resonance Spectroscopy

Kevin K. Lehmann

Abstract

This paper presents lineshapes for molecular Optical-Optical Double Resonance (DR) Spectroscopy with arbitrary strength for both pump and probe field using the steady-state solutions for the 3-level density matrix. When the Doppler broadening can be neglected, the results are analytical, and the probe spectrum is a pair of Lorentzian lines that display Autler-Townes splitting, and each has an angular frequency half-width half maximum equal to the relaxation rates, which are all assumed equal. When Doppler broadening is introduced, one must resort to numerical integration except for the limit of weak pump and probe fields. When the Doppler width is assumed much larger than the pump and probe Rabi Frequencies, the calculated DR lineshapes are found to be Lorentzian with a strong pump field limit that is proportional to the pump Rabi frequency, what is commonly known as power broadening. However, the width does not equal the Rabi frequency and is different for co- and counter-propagating pump and probe fields. Furthermore, that broadening is largely inhomogeneous, despite the Lorentzian shape. The saturation power is found to be about 4 times higher than for the bare probe transition with the same relaxation rate, dramatically lower than that expected if the width is interpreted as homogeneous.

Theory of Lineshapes in Optical-Optical Double Resonance Spectroscopy

Abstract

This paper presents lineshapes for molecular Optical-Optical Double Resonance (DR) Spectroscopy with arbitrary strength for both pump and probe field using the steady-state solutions for the 3-level density matrix. When the Doppler broadening can be neglected, the results are analytical, and the probe spectrum is a pair of Lorentzian lines that display Autler-Townes splitting, and each has an angular frequency half-width half maximum equal to the relaxation rates, which are all assumed equal. When Doppler broadening is introduced, one must resort to numerical integration except for the limit of weak pump and probe fields. When the Doppler width is assumed much larger than the pump and probe Rabi Frequencies, the calculated DR lineshapes are found to be Lorentzian with a strong pump field limit that is proportional to the pump Rabi frequency, what is commonly known as power broadening. However, the width does not equal the Rabi frequency and is different for co- and counter-propagating pump and probe fields. Furthermore, that broadening is largely inhomogeneous, despite the Lorentzian shape. The saturation power is found to be about 4 times higher than for the bare probe transition with the same relaxation rate, dramatically lower than that expected if the width is interpreted as homogeneous.

Paper Structure

This paper contains 7 sections, 11 equations, 18 figures.

Figures (18)

  • Figure 1: Level Diagram for Ladder-type Double Resonance
  • Figure 2: Double Resonance Excitation Spectrum for on-resonance pumping
  • Figure 3: Double Resonance Excitation Spectra for for multiple pump detuning values
  • Figure 4: Double Resonance Excitation Spectra at multiple Pump levels
  • Figure 5: Double Resonance off-pump resonance Excitation Spectra at multiple Pump levels
  • ...and 13 more figures