Table of Contents
Fetching ...

MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising

Peiyuan Jing, Chun-Wun Cheng, Liutao Yang, Zhenxuan Zhang, Thiago V. Lima, Klaus Strobel, Antoine Leimgruber, Angelica Aviles-Rivero, Guang Yang, Javier A. Montoya-Zegarra

TL;DR

MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising, introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states.

Abstract

Low-dose Positron Emission Tomography (PET) reduces radiation exposure but suffers from severe noise and quantitative degradation. Diffusion-based denoising models achieve strong final reconstructions, yet their reverse trajectories are typically unconstrained and not aligned with the progressive nature of PET dose formation. We propose MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising. MAP-Diff introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states. Anchor timesteps are calibrated via degradation matching between simulated diffusion corruption and real multi-dose PET pairs, and a timestep-weighted anchor loss stabilizes stage-wise learning. At inference, the model requires only ultra-low-dose input while enabling progressive, dose-consistent intermediate restoration. Experiments on internal (Siemens Biograph Vision Quadra) and cross-scanner (United Imaging uEXPLORER) datasets show consistent improvements over strong CNN-, Transformer-, GAN-, and diffusion-based baselines. On the internal dataset, MAP-Diff improves PSNR from 42.48 dB to 43.71 dB (+1.23 dB), increases SSIM to 0.986, and reduces NMAE from 0.115 to 0.103 (-0.012) compared to 3D DDPM. Performance gains generalize across scanners, achieving 34.42 dB PSNR and 0.141 NMAE on the external cohort, outperforming all competing methods.

MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising

TL;DR

MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising, introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states.

Abstract

Low-dose Positron Emission Tomography (PET) reduces radiation exposure but suffers from severe noise and quantitative degradation. Diffusion-based denoising models achieve strong final reconstructions, yet their reverse trajectories are typically unconstrained and not aligned with the progressive nature of PET dose formation. We propose MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising. MAP-Diff introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states. Anchor timesteps are calibrated via degradation matching between simulated diffusion corruption and real multi-dose PET pairs, and a timestep-weighted anchor loss stabilizes stage-wise learning. At inference, the model requires only ultra-low-dose input while enabling progressive, dose-consistent intermediate restoration. Experiments on internal (Siemens Biograph Vision Quadra) and cross-scanner (United Imaging uEXPLORER) datasets show consistent improvements over strong CNN-, Transformer-, GAN-, and diffusion-based baselines. On the internal dataset, MAP-Diff improves PSNR from 42.48 dB to 43.71 dB (+1.23 dB), increases SSIM to 0.986, and reduces NMAE from 0.115 to 0.103 (-0.012) compared to 3D DDPM. Performance gains generalize across scanners, achieving 34.42 dB PSNR and 0.141 NMAE on the external cohort, outperforming all competing methods.
Paper Structure (17 sections, 6 equations, 3 figures, 2 tables)

This paper contains 17 sections, 6 equations, 3 figures, 2 tables.

Figures (3)

  • Figure 1: Overview of MAP-Diff. (a) Conceptual comparison between standard diffusion training with end-point supervision and the proposed multi-anchor trajectory-level supervision. (b) MAP-Diff training strategy with timestep zoning and anchor-weighted loss. (c) Progressive inference trajectory enabling dose-consistent intermediate outputs.
  • Figure 2: Visual comparison of PET denoising across methods.
  • Figure 3: Intermediate-dose reconstruction accuracy at anchor timesteps. (a) Quantitative comparison against paired real-dose references at the 1/10, 1/4, and 1/2 dose levels. (b) Coronal-view signed error maps against paired real-dose references.