Table of Contents
Fetching ...

Circulating Currents in Electric Machines: Positive Impact of The End Windings Length on Losses

Taha El Hajji, Antti Lehikoinen, Anouar Belahcen

Abstract

Circulating currents occurring in windings of electric machines received rising interest recent years. Circulating currents represent unwanted currents flowing between parallel-connected conductors. This phenomenon is due to various reasons such as asymmetries in the winding and differences in electric potential between parallel-connected conductors. This effect occurs both at no-load and on-load conditions, and always lead to uneven distribution of the current between the parallel conductors, therefore leading to higher losses, as proven in the authors' previous work. Circulating currents are occurring mainly due to asymmetries and electric potential difference in the active part, meaning that long end windings are advantageous to mitigate the effect of circulating currents. Losses due to circulating currents decrease at a rate proportional to the inverse square of the end windings length. The aim of this paper is to mathematically prove this property and present a case study application in an electric machine.

Circulating Currents in Electric Machines: Positive Impact of The End Windings Length on Losses

Abstract

Circulating currents occurring in windings of electric machines received rising interest recent years. Circulating currents represent unwanted currents flowing between parallel-connected conductors. This phenomenon is due to various reasons such as asymmetries in the winding and differences in electric potential between parallel-connected conductors. This effect occurs both at no-load and on-load conditions, and always lead to uneven distribution of the current between the parallel conductors, therefore leading to higher losses, as proven in the authors' previous work. Circulating currents are occurring mainly due to asymmetries and electric potential difference in the active part, meaning that long end windings are advantageous to mitigate the effect of circulating currents. Losses due to circulating currents decrease at a rate proportional to the inverse square of the end windings length. The aim of this paper is to mathematically prove this property and present a case study application in an electric machine.

Paper Structure

This paper contains 6 sections, 26 equations, 5 figures.

Figures (5)

  • Figure 1: Phase bundle composed of $Nsh$ parallel strands
  • Figure 2: Illustration of the ratio $\alpha_w$
  • Figure 3: (a) S-PMSM arxiv_taha_2024_1 and (b) Slot Layout with specified locations of the strands arxiv_taha_2024_1
  • Figure 4: Losses due to circulating currents with respect to (a) $\alpha_w$ and (b) $\frac{1}{\alpha_w^2}$
  • Figure 5: Waveforms of the currents in the parallel strands for each phase for (a) $\alpha_w=2$, (b) $\alpha_w=2.5$, (c) $\alpha_w=3$

Theorems & Definitions (3)

  • Definition
  • Definition
  • proof